plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Bosch Alternators|Page 2640 > < Bosch Alternators|Page 2638
Page 4
background image

Fig. 4 Charging circuit resistance test. Models w/integral regulator

1.

Disconnect ground cable from battery and the "Bat" lead from alternator output terminal.

2.

Complete test connections as shown.

3.

Connect battery ground cable, then start engine and operate at idle.

4.

Adjust engine speed and carbon pile rheostat to obtain 20 amps in the circuit and check voltmeter reading. Reading should not exceed 0.5 volts. If
a higher voltage drop is indicated, inspect, clean and tighten all connections in the circuit. A voltage drop test at each connection can be performed
to isolate the problem.

Current Output Test

Fig. 5 Current output test. Models w/integral regulator

1.

Disconnect ground cable from battery and the "Bat" lead from alternator output terminal.

2.

Complete test connections as shown.

3.

Connect battery ground cable, then start engine and operate at idle.

Bosch Alternators|Page 2640 > < Bosch Alternators|Page 2638