All Technical Service Bulletins for Alignment: > < Alignment - Insufficient Positive Camber Adjustment
Page 2
background image

NOTE:

THE UPPER CONTROL ARM SPACERS ARE TO BE USED ONLY AS A SET (1 LONG AND 1 SHORT) ON THE
SIDE WHERE THEY ARE NEEDED. UNDER NO CIRCUMSTANCES ARE SPACERS TO BE STACKED TO
GAIN ADDITIONAL POSITIVE CAMBER ADJUSTMENT.

POLICY:

Reimbursable within the provisions of the warranty

TIME ALLOWANCE:
Labor Operation No.

02-10-55-90 . . . . . . . . .   

1.8 Hrs.

Includes Shim One Side and Align Front End

02-10-55-91 . . . . . . . . .   

2.5 Hrs.

Includes Shim Both Sides and Align Front End

FAILURE CODE:

50 - Improper Adjustment

All Technical Service Bulletins for Alignment: > < Alignment - Insufficient Positive Camber Adjustment