plymouth Workshop Repair Guides

Plymouth Grand Fury/Salon V8-318 52L VIN S Workshop Manuals

Thermostatic Air Cleaner > < Positive Crankcase Ventilation|Description and Operation|Page 1937
Page 1
background image

Positive Crankcase Ventilation: Service and Repair

    Every 30,000 miles, replace PCV valve and clean crankcase inlet air cleaner. If vehicle is used extensively for short trips with frequent idling, this
service may have to be performed sooner.
    To clean the passage in the carburetor, remove carburetor from engine. Turn a 1/4 inch drill bit by hand through the passage to dislodge the solid
particles, then blow clean using compressed air. If necessary, use a smaller drill bit so that no metal will be removed.

Thermostatic Air Cleaner > < Positive Crankcase Ventilation|Description and Operation|Page 1937