Blower Motor: Description and Operation
Low Speed

CIRCUIT OPERATION

When the operator selects the LOW speed position, power Is supplied on circuit C71 through the blower motor to circuit C7. The C7 circuit
connects from the blower motor to the HVAC control, HIGH speed contact.

Voltage is passed through the HVAC control to circuit C107. The C107 circuit connects from the HVAC control to the blower motor resistor.

The voltage is passed through the blower motor resistor to circuit C4 which connects from the resistor back to the HVAC control and to ground on
circuit Z1.