system must be able to bring the evaporator temperature down a predetermined minimum amount in less than 2 minutes.

NOTE:  Cool-down will not occur on Heater Only units.

CALIBRATION/COOL-DOWN LED DISPLAY CODES

Calibration/Cooldown Test LED's

NOTE:  See chart for definition of flashing LED's. If no problems are found, the control functions normally.

CALIBRATION/DIAGNOSTICS TEST ENTRY

TO INITIATE TESTS:

^

Set Blower motor ON HIGH

^

Set Mode position to Panel

^

Open all A/C outlets

^

Set Temperature to Cold (Both slide pots if equipped)

^

Depress WASH and REAR WIPER button simultaneously for 5 Seconds (Until all LED's light)

RESULTS:

^

All LED's will turn on for 5 Seconds

^

Calibration Test is running when REAR WIPER and INTERMITTENT are alternately flashing. Cool-down test is running if A/C and RECIRC
are alternately flashing.

^

Acceptable result is REAR WIPER LED is the only LED flashing. Push Rear Wiper to exit.

^

After all tests have passed, Calibration Diagnostics and Cool-down can be run separately.

Battery Charging

WARNING:  DO NOT CHARGE A BATTERY THAT HAS EXCESSIVELY LOW ELECTROLYTE LEVEL. BATTERY MAY SPARK
INTERNALLY AND EXPLODE. EXPLOSIVE GASES FORM OVER THE BATTERY. DO NOT SMOKE, USE FLAME, OR CREATE
SPARKS NEAR BATTERY. DO NOT ASSIST BOOST OR CHARGE A FROZEN BATTERY. BATTERY CASING MAY FRACTURE.
BATTERY ACID IS POISON, AND MAY CAUSE SEVERE BURNS. BATTERIES CONTAIN SULFURIC ACID. AVOID CONTACT WITH
SKIN, EYES, OR CLOTHING. IN THE EVENT OF CONTACT, FLUSH WITH WATER AND CALL PHYSICIAN IMMEDIATELY. KEEP
OUT OF REACH OF CHILDREN
.

Visual Inspection and Service|Page 7470 > < Visual Inspection and Service|Page 7468