Canister Purge Solenoid: Service and Repair

Fig 112  Duty Cycle EVAP Purge Solenoid Valve

REMOVAL

1. Remove vacuum hose and electrical connector from solenoid (Fig. 112).
2. Pull solenoid up to remove it from mounting bracket.

INSTALLATION

Reverse above procedure for installation.