Auxiliary Power Outlet: Description and Operation

CIRCUIT OPERATION

The cigar lighter and/or power outlet(s) are powered by a relay located in the Power Distribution Center (PDC).

Power for the coil side of the relay is supplied on circuit F1. This circuit is HOT in the ACCESSORY and RUN positions only and protected by a 
6 amp Positive Temperature Coefficient (PTC) located in PTC cavity 7 of the junction block.

Circuit A31 is used to connect the PTC to the ignition switch. Battery Voltage for the A31 circuit is supplied on circuit A1. This circuit is
protected by a 40 amp fuse located in cavity 5 of the Power Distribution Center (PDC).

Ground for the coil side of the relay is supplied on circuit Z1. This circuit terminated at the left cowl panel.

When the ignition switch is in the ACCESSORY or RUN position, Voltage flowing through the relay coil causes the contacts in the relay to
CLOSE connecting circuits #6 and F30.

Circuit #6 is protected by a 20 amp fuse located in cavity 21 of the PDC. Circuit F30 connects from the relay to the cigar lighter(s)/power outlet
(s). Ground for the cigar lighter(s)/power outlet(s) is supplied on circuit Z1.