plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Hydraulic Control Assembly - Antilock Brakes > < With Antilock Brakes|Page 4138
Page 2
background image

Actuator Attachment To Proportioning Valve

5. Remove the hooked end of the proportioning valve actuator from the isolator bushing on the lever of the height proportioning valve.

INSTALLATION

1. Install the hooked end of the actuator on the proportioning valve lever. Be sure isolator bushing on lever of proportioning valve is fully seated in

hook of actuator.

NOTE:  When installing height sensing proportioning valve on mounting bracket be sure proportioning valve shield is installed between the
proportioning valve and the mounting bracket.

2. Install height sensing proportioning valve on mounting bracket. Install the proportioning valve attaching bolts. Tighten the attaching bolts to a

torque of 23 Nm (200 inch lbs.).

3. Install the 4 chassis brake lines into the inlet and outlet ports of the proportioning valve. Tighten all 4 line nuts to a torque of 16 Nm (142 inch

lbs.).

4. Adjust the proportioning valve actuator.
5. Bleed the brake system thoroughly to ensure that all air has been expelled from the hydraulic system. See Brake Bleeding for the proper bleeding

procedure.

6. Lower the vehicle to the ground.
7. Road test the vehicle to verify proper operation of the vehicles brake system.

Hydraulic Control Assembly - Antilock Brakes > < With Antilock Brakes|Page 4138