Keyless Entry: Description and Operation
Power Door Locks

CIRCUIT OPERATION

Power for the Remote Keyless Entry (RKE) module is supplied from three sources.

Power is supplied to the RKE module on circuit G5. This circuit is protected by a 5 Amp fuse located in cavity 11 of the fuse block. Power for the
fuse is supplied from the ignition switch on circuit A21. This circuit is HOT in the START and RUN position.

Power for the A21 circuit is supplied by circuit A1. This circuit is HOT at all times and is protected by a 30 Amp fuse located in the Power
Distribution Center (PDC).

Circuit F35 supplies battery voltage to the RKE module. This circuit is HOT at all times and is protected by a 20 Amp fuse located in cavity 3 of
the fuse block. Power for the fuse is supplied on circuit A3. The A3 circuit is protected by a 40 Amp fuse located in the PDC.

The F35 circuit is used to supply power for the contact side of several relays internal to the RKE module.

Power is also supplied by circuit M1. This is the Ignition-Off Draw (IOD) circuit and is protected by a 10 Amp fuse located in cavity 13 of the
Power Distribution Center (PDC).