Circuit P35 connects from the module to the passengers and drivers door switch, lock side.

Power is passed through the bus bar in the passengers switch to circuit P33. This circuit connects to the LOCK side of the motors.

Ground for the motors is supplied on circuit P34 through a bus bar in the right switch to circuit P36.

The P36 circuit connects from the switch to the UNLOCK-ALL relay in the RKE module. Ground is passed through the normally CLOSED
contacts in the relay to the left door switch.

Ground is passed through a bus bar in the switch to circuit Z8. This circuit terminates at the instrument panel left center support.

Unlock-All

CIRCUIT OPERATION

When the operator selects UNLOCK ALL the Remote Keyless Entry (RKE)module energizes the unlock all relay connecting circuits F35 and
P36. Circuit P36 connects from the module to the passengers and drivers door switch, unlock side.

Power is passed through the bus bar in the passengers switch to circuit P34. This circuit connects to the UNLOCK side of the motors.

Ground for the motors is supplied on circuit P33 through a bus bar in the right switch to circuit P35. The P35 circuit connects from the switch to
the LOCK-ALL relay in the RKE module. Ground is passed through the normally CLOSED contacts in the relay to the left door switch.

Ground is passed through a bus bar in the switch to circuit Z8. This circuit terminates at the instrument panel left center support.