Hazard Warning Flasher: Description and Operation
Hazard Flashers Description

HAZARD FLASHERS

Circuit L9 from the Power Distribution Center (PDC) supplies battery voltage for the hazard flashers. A 10 amp micro fuse in the PDC protects
circuit L9.

Circuit L9 connects to pin 6 of the multi-function switch. With the hazard flashers on, the multi-function switch connects circuits L9 and L55.

Circuit L55 feeds the combination flasher unit. Circuit Z2 provides ground for the flasher unit.

From the flasher unit, circuit L32 connects to cavity 3 of the multi-function switch. With the hazard flashers on, the multi-function switch connects
circuit L32 to circuits L60, L61, L62, and L63.

Circuit L60 supplies voltage to the right front turn signal/hazard lamp. The L60 circuit splices to the instrument cluster to power the right indicator
lamp. Circuit L60 connects to cavity 6 of the multi-function switch connector.

Circuit L61 supplies voltage to the left front turn signal/hazard lamp. The L61 circuit splices to the instrument cluster to power the left indicator
lamp. Circuit L61 connects to cavity 10 of the multi-function switch connector.

Circuit L62 supplies voltage to the right rear turn signal/hazard flasher/stop lamp. Circuit L62 connects to cavity 4 of the multi-function switch
connector.

Circuit L63 supplies voltage to the left rear turn signal/hazard/flasher/stop lamp. Circuit L63 connects to cavity 9 of the multi-function switch
connector.