Powertrain Control Module: Description and Operation
PCM Related Trouble Code Messages

Internal Controller Failure

NAME OF CODE:

Internal Controller Failure

WHEN MONITORED:

With the ignition ON.

SET CONDITION:

There is an Eraseable Programable Read Only Memory (EPROM) sum check failure at power down.

THEORY OF OPERATION:

This code indicates the EPROM memory may be corrupt.

POSSIBLE CAUSES:

-

Failed Powertrain Control Module (PCM)

PCM Failure EEPROM Write Denied

NAME OF CODE:

PCM Failure EEPROM Write Denied

WHEN MONITORED:

With the ignition ON, SBEC tries to write to EEPROM memory.

SET CONDITION:

Unsuccessful attempt to write to EEPROM memory.

POSSIBLE CAUSES:

-

PCM failure

-

Busy bus

PCM Failure SPI Communications

NAME OF CODE:

PCM Failure SPI Communications

WHEN MONITORED:

With the ignition ON.

SET CONDITION:

Serial communications inside the controller fail eight times during a run cycle.

THEORY OF OPERATION:

Communications between microprocessors inside the Powertrain Control Module (PCM) are needed to operate the total system. If failure occurs,
the solenoids and relays may not actuate properly.

POSSIBLE CAUSES:

-

PCM failure

PCM Failure SRI Mile Not Stored

NAME OF CODE:

PCM Failure SRI Mile Not Stored

WHEN MONITORED:

With the ignition ON SBEC tries to write service reminder indicator mileage to EEPROM memory.

SET CONDITION:

Unsuccessful attempt to write to EEPROM memory.

POSSIBLE CAUSES:

-

PCM failure

-

Busy bus