plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

All Technical Service Bulletins: > < Vehicle - No Crank/No Start/Solenoid Clicks
Page 2
background image

CAUTION

IT IS CRITICAL THAT THE GENERATOR OUTPUT TERMINAL BE CONNECTED TO THE BATTERY POSITIVE TERMINAL OF THE 
STARTER SOLENOID, FOR PROPER OPERATION OF THE CHARGING AND CRANKING SYSTEMS.

14.

Connect the push-on solenoid connector.

15.

Position the starter face into the transmission housing. Support the starter in pilot and start the top bolt.

16.

Attach the ground cable to the lower mounting bolt and start bolt.

17.

Ensure the proper starter alignment before torquing the starter mounting bolts to 54 Nm (40 ft. lbs.).

18.

Vehicles equipped with A/C:

^

Using a floor jack or jack stand, raise the engine and transmission assembly to the original position.

^

Install the front engine mount bolt through the insulator and front crossmember mounting bracket.

^

Torque the bolt to 54 Nm (40 ft. lbs.)

19.

Lower vehicle and connect battery cables.

POLICY: Reimbursable within the provisions of the warranty.

TIME ALLOWANCE:

Labor Operation No:

08-75-01-91

0.8 Hrs.

FAILURE CODE:

P8 - New Part

All Technical Service Bulletins: > < Vehicle - No Crank/No Start/Solenoid Clicks