Air Door Cable: Adjustments
Temperature Control Cable Adjustment

1. Attach cable to actuator arm on temperature door and clip black casing against the stop.
2. Attach other end of cable to instrument panel control.
3. Turn the temperature knob completely counterclockwise.
4. While holding the knob in the counterclockwise position pull on the black casing of the temperature cable. This will take up any free play in the

cable and index the temperature door to the temperature knob.

5. Then snap the cable hold down clip into position.
6. Remount control.