plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Blower Motor - Inoperative In Freezing Temps|Page 5367 > < Blower Motor - Inoperative In Freezing Temps|Page 5361
Page 1
background image

Blower Motor: All Technical Service Bulletins
Blower Motor - Inoperative In Freezing Temps

NO: 24-03-97

GROUP: Heating & A/C

DATE: Mar. 14, 1997

SUBJECT:

Blower Motor Does Not
Operate In Freezing
Temperatures

THIS BULLETIN SUPERSEDES TECHNICAL SERVICE BULLETIN 24-20-96 DATED DECEMBER 20, 1996, WHICH SHOULD BE NOTED IN
THE 1996 TECHNICAL SERVICE BULLETIN MANUAL (PUBLICATION NO. 81-699-97010). A BLOWER MOTOR FOR A/C EQUIPPED
VEHICLES HAS BEEN ADDED. 
MODELS:

1995 - 1997 (PL) Neon

NOTE:

THIS BULLETIN APPLIES TO VEHICLES BUILT AFTER JULY 1, 1994 (MDH 07-01-XX), OR VEHICLES BUILT PRIOR TO JULY 1, 1994
(MDH 07-01-XX) THAT HAVE HAD TECHNICAL SERVICE BULLETIN 23-48-94 PERFORMED. TECHNICAL SERVICE BULLETIN
23-48-94 INCLUDES THE INSTALLATION OF A DRAIN TUBE.

SYMPTOM/CONDITION:

Blower motor may be inoperable in temperatures at/or below freezing.

DIAGNOSIS:

Inspect the blower motor fuse. If blown, inspect the blower motor for presence of ice or water. It may be necessary to park the vehicle in a warm area to
allow the blower motor to begin to thaw and water to run out to verify the failure mode. If water or ice is found perform the Repair Procedure.

PARTS REQUIRED:

**AR(1)

04644918

Blower Motor (With Air Conditioning)**

AR(1)

04644545

Blower Motor (Without Air Conditioning)

AR(1)

04687835

Fuse, Blower Motor

AR(1)

04783100

Drain Tube

REPAIR PROCEDURE:

This bulletin involves the positioning of the drain tube assembly and the replacement of the blower motor and blower motor fuse.

Blower Motor - Inoperative In Freezing Temps|Page 5367 > < Blower Motor - Inoperative In Freezing Temps|Page 5361