Low Pressure Sensor / Switch: Service and Repair

The low pressure cut out switch is a sealed factory calibrated unit. It must be replaced if defective.

WARNING: The refrigeration system must be completely recovered before proceeding with this operation.

REMOVAL

1. Disconnect the boot like wire connector at the cut off switch.

Low Pressure Cut Off Switch

2. Using a sender unit removal socket, remove the switch from the expansion valve.

INSTALLATION

NOTE:  Verity the 0-ring condition on the replacement switch.

For installation, reverse the above procedures. Evacuate and charge the system.