plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Air Injection Pump > < Air Switching Valve|Page 1685
Page 1
background image

Air Injection Control Valve: Service and Repair

1.

Remove air and vacuum hoses from air switching valve.

2.

Remove valve attaching screws, then the valve.

3.

Remove gasket material from valve and mounting surface.

4.

Reverse procedure to install, using a new gasket. Torque attaching screws to 125 inch lbs.

Air Injection Pump > < Air Switching Valve|Page 1685