Thermostatic Air Cleaner: Testing and Inspection
Power Heat Control Valve

    To determine if the valve has failed, remove the vacuum line from the valve and apply a vacuum of 6 inches Hg to the valve. If the valve does not fully
close, it is defective and must be replaced.