plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Bosch, Mitsubishi & Nippondenso Starters|Page 2838 > < Bosch, Mitsubishi & Nippondenso Starters|Page 2836
Page 3
background image

Fig. 3 Circuit resistance chart. 1980-85

Circuit Resistance Test

1.

Connect voltmeter leads across each connection shown in circuit resistance chart.

2.

If readings are higher than specified, clean or repair connection, then repeat test.

Starter Solenoid Test

1.

Connect heavy jumper wire on starter relay between battery and solenoid terminals.

2.

If starter does not crank, or solenoid chatters, check wiring and connectors from relay to starter for loose or corroded connections, then repeat test.

3.

If engine still will not crank, repair or replace starter as necessary.

Starter Relay Test (Automatic Transmissions)

1.

Place transmission in Neutral, then connect jumper wire on starter relay between battery and ignition terminals.

2.

If engine does not crank, connect a second jumper wire on starter relay between ground terminal and good ground.

3.

Repeat test. If engine cranks, transmission linkage is misadjusted or neutral safety switch is defective. If engine does not crank, starter relay is
defective.

Starter Relay Test (Manual Transmissions)

1.

Depress clutch pedal, then connect suitable jumper wire on starter relay between battery and ignition terminals.

2.

If engine cranks, starter relay is satisfactory. If engine does not crank, connect a second jumper on starter relay between ground terminal and good
ground, then repeat test.

3.

If engine does not crank, starter relay is defective and should be replaced.

Bosch, Mitsubishi & Nippondenso Starters|Page 2838 > < Bosch, Mitsubishi & Nippondenso Starters|Page 2836