plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Radiator Hose > < Radiator Cap|Specifications
Page 1
background image

Radiator Cap: Testing and Inspection

The pressure cap upper gasket (seal) pressure relief can be checked by removing cap. Attach the Radiator Pressure Tool to the cap and pump air into
the cap. Pressure cap upper gasket should relieve at 124 kPa (18 psi) and hold pressure at 110 kPa (16 psi) minimum.

Pressure Cap

Remove the pressure tester hold the cap in hand right side up. The vent valve at the bottom of the cap should not open. If the rubber gasket has
swollen and prevents the valve from closing, replace the cap.
Hold the cleaned cap in hand upside down. If any light can be seen between vent valve and rubber gasket, replace cap.

WARNING: THE WARNING WORDS DO NOT OPEN HOT ON THE COOLANT BOTTLE PRESSURE CAP IS A SAFETY
PRECAUTION. WHEN HOT, PRESSURE BUILDS UP IN COOLING SYSTEM. TO PREVENT SCALDING OR INJURY, THE
COOLANT BOTTLE PRESSURE CAP SHOULD NOT BE REMOVED WHILE THE SYSTEM IS HOT AND/OR UNDER PRESSURE.
 

There is no need to remove the pressure cap at any time except for the following purposes:
^

Checking and adjust antifreeze freeze point.

^

Refilling system with new coolant.

^

Conducting service procedures.

^

Checking for vacuum leaks.

WARNING: IF VEHICLE HAS BEEN RUN RECENTLY, WAIT 15 MINUTES BEFORE REMOVING CAP. THEN PLACE A SHOP
TOWEL OVER THE CAP AND WITHOUT PUSHING DOWN ROTATE IT COUNTERCLOCKWISE TO THE FIRST STOP. ALLOW
FLUIDS TO ESCAPE THROUGH THE OVERFLOW TUBE AND WHEN THE SYSTEM STOPS PUSHING OUT COOLANT AND
STEAM AND PRESSURE DROPS, REMOVE THE CAP COMPLETELY. SQUEEZING THE RADIATOR INLET HOSE WITH A SHOP
TOWEL (TO CHECK PRESSURE) BEFORE AND AFTER TURNING TO THE FIRST STOP IS RECOMMENDED.
 