Prowler V6-3.5L VIN G (1999)
Fuel Gauge Sender: Service and Repair
Fig. 26 Fuel Pump/Level Sensor Electrical Connector
REMOVAL
1. Remove fuel pump module.
2. Depress retaining tab and remove the fuel pump/level sensor connector from the BOTTOM of the fuel pump module electrical connector.
NOTE: The pump module harness on TOP of flange is not serviceable or removable.
Fig. 27 Terminal Removal Tool
3. Using Special Tool C-4334 terminal remover or equivalent, remove terminals from level sensor connector.
Fig. 28 Loosening Level Sensor
4. Insert a screwdriver between the fuel pump module and the top of the level sensor housing. Push level sensor down slightly