plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Fuel Gauge Sender|Specifications|Page 5172 > < Fuel Gauge Sender|Specifications|Page 5170
Page 1
background image

Fuel Gauge Sender: Service and Repair

Fig. 26 Fuel Pump/Level Sensor Electrical Connector

REMOVAL

1. Remove fuel pump module.
2. Depress retaining tab and remove the fuel pump/level sensor connector from the BOTTOM of the fuel pump module electrical connector.

NOTE:  The pump module harness on TOP of flange is not serviceable or removable.

Fig. 27 Terminal Removal Tool

3. Using Special Tool C-4334 terminal remover or equivalent, remove terminals from level sensor connector.

Fig. 28 Loosening Level Sensor

4. Insert a screwdriver between the fuel pump module and the top of the level sensor housing. Push level sensor down slightly

Fuel Gauge Sender|Specifications|Page 5172 > < Fuel Gauge Sender|Specifications|Page 5170