Instrument Panel Circuit Board: Service and Repair
Fuel and Temp PC Board

REMOVAL

1. Open hood.
2. Disconnect and isolate the negative battery cable.
3. Remove cluster. Refer to Instrument Cluster Removal and Installation.
4. Remove four cluster back cover retaining screws and remove the cover.
5. Disconnect the wire connector from the fuel and temp printed circuit board to the speedometer printed circuit board.

Fuel And Temperature Printed Circuit Board

6. Remove two printed circuit board attaching screws and remove two screws located at the base of the connector.
7. Remove PC board.

INSTALLATION

-

For installation, reverse the above procedures.