plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Receiver Dryer > < A/C, Heater Housing - Water Leaks Onto Floor Carpet|Page 3402
Page 4
background image

FIGURE 3

6.

Install new air intake shield, PN 4462121 (Figure 3).

7.

Clean surface and apply RTV sealer as required to completely seal around the air intake shield mounting screws after installation. Also seal the
outboard top corner of the air intake shield (Figure 3).

8.

Reinstall cowl-plenum grille and windshield wiper arm assemblies.

9.

Water test vehicle to insure leak is corrected.

POLICY:

Reimbursable within the provisions of the warranty

TIME ALLOWANCE:
Labor Operation No.

23-02-08-90 . . . . . . . . . . . . . . . .     

0.4 Hrs.

FAILURE CODE: 4X - Water Leak
The time allowance for performing this repair has been revised. Investigation of the original time allowance revealed that additional time was required to
properly perform the repair.

The revised time allowance is listed below and should be place of the previous issued figure.

TIME ALLOWANCE:
Labor Operation No.

23-02-08-90 . . . . . . .    

0.8 Hrs.

FAILURE CODE:

4X - Water Leak

Receiver Dryer > < A/C, Heater Housing - Water Leaks Onto Floor Carpet|Page 3402