Pulsair Valve: Description and Operation

Fig. 6 Aspirator valve

    The valve, Fig. 6, in this system uses exhaust pressure pulsations to draw air into the exhaust system to reduce CO and HC emissions. It draws fresh
air from the ``clean'' side of the air cleaner and past a one-way spring loaded diaphragm. The diaphragm opens to permit fresh air to mix with the exhaust
gases during negative pressure (vacuum) pulses. When the pressure is positive, the diaphragm closes and no exhaust gases are allowed to flow past the
valve. The aspirator valve works most efficiently at idle and slightly above idle when the negative pulses are maximum. At higher engine speeds, the
aspirator valve remains closed.