Fillpipe Restrictor: Testing and Inspection

Fill Pipe Restrictor

 

Use dowel gauge to check restrictor opening [1].

 

Inspect for; tampering, broken flapper, excessive wear etc..

 
REMARKS:

 
[1]  N&W Manufacturing part number ---> FRG-95, or equivalent, (must be made of non-sparking material, 1552 alloy suggested).
 

^

Minimum tool diameter .9375"

^

Maximum tool diameter .9500"