plymouth Workshop Repair Guides

Plymouth Workshop Service and Repair Manuals

Electrical Specifications|Page 3800 > < Neutral Safety Switch|Locations|Page 3795
Page 1
background image

Starter Motor: Electrical Specifications
Amperage Draw Test

Amperage Draw Test 

Bosch

Nippondenso 

   

  

  

 

Identification Number

5213045

5213645 

   

  

  

 

Cranking Amperage Draw Test

120-160 A

120-160 A 

Note: Engine should be at normal operating temperature.

 

   

  

  

 

Free Speed Test

47 A at 6600 rpm

47 A at 6600 rpm 

Note:  Maximum current drawn.

Note:  Minimum RPM.  At 11 volts.

Note:  Minimum RPM.  At 11 volts.

 

   

  

  

 

Electrical Specifications|Page 3800 > < Neutral Safety Switch|Locations|Page 3795