Voyager V6-201 3.3L VIN R SMFI (1997)
Generator: Testing and Inspection
Alternator Output Wire Resistance Test
TEST PROCEDURE
1. Disconnect battery ground cable.
2. Disconnect "B+" lead at alternator output terminal.
Fig 2 Alternator Output Wire Resistance Test