6000 V6-173 2.8L VIN W FI (1986)
Figure 3
4.
Replace both the pump motor 30 amp fuse and the ABS 30 amp main fuse (See figures 2 and 3).
CAUTION: FAILURE TO FULLY DEPRESSURIZE THE HYDRAULIC ACCUMULATOR BEFORE PERFORMING SERVICE
OPERATIONS COULD RESULT IN INJURY TO SERVICE PERSONNEL AND DAMAGE TO PAINTED SURFACES.
Figure 5
5.
Visually inspect hydraulic pump and motor housing for any evidence of brake fluid seepage below pressure/warning switch. If any components
require replacement, care should be taken to prevent brake fluid spillage onto motor (See figure 5).
A.
If any evidence of brake fluid seepage is indicated, perform following steps as indicated in the 1987 Pontiac 6000 Service Manual pages 5E -
5, 6 & 7. If no seepage is indicated, proceed to step 5B.