pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

A/T - THM 440-T4 Erratic Shifts/No Upshifts|Page 4567 > < A/T - THM 440-T4 Erratic Shifts/No Upshifts
Page 2
background image

Figure 3 - Governor Oil Pipe And Accumulator Assembly

SERVICE ACTION:

(Figures 2 and 3)

1.

Remove governor assembly (5) from transaxle and clean with solvent.

2.

Inspect governor for binding weights and/or mispositioned springs. To verify operation, turn governor upside down and pour solvent into the
governor shaft. Check for leakage past the checkballs. If leakage is noted, replace the governor assembly.

3.

Reinstall governor cover (9) without the governor assembly.

4.

Start the engine and move the selector lever to Drive (D) position. Allow the engine to run for 15-20 seconds.

5.

Move the selector lever to Park (P) and stop the engine.

6.

Reinstall the governor assembly (5) into the transaxle and road test the vehicle to verify transaxle operation.

If erratic shifts or a no upshift condition continues:

7.

Remove and clean governor oil pipe retainer (129), orificed cup plug (127), governor feed and return pipes (125, 124) accumulator cover (121)
and governor screen (126).

A/T - THM 440-T4 Erratic Shifts/No Upshifts|Page 4567 > < A/T - THM 440-T4 Erratic Shifts/No Upshifts