Fluid Pump: Customer Interest
A/T - Fluid Exhausting Out the Vent Pipe

Number

84-7-24

Date 6/84

Subject:

TRANSMISSION OIL EXHAUSTING OUT THE VENT PIPE - ALL 1983 AND 1984 THM 200C

If a 1983 or 1984 THM 200-C transmission exhibits oil exhausting out the vent pipe, possible causes may be due to out-of-flat conditions on the face,
nicked faces, porosity, or face damage on the Pump Body Assembly or the Oil Pump Cover Assembly.

When servicing any 1983 or 1984 THM 200-C transmission for transmission oil exhausting out the vent pipe, both the Pump Body Assembly and the
Pump Cover assembly should be replaced. At the same time, a new Pump to Case gasket should also be installed. Replacement of these parts will prevent
transmission oil from exhausting out the vent pipe during harsh deceleration or during sharp turns.

The following part numbers can be used to service all these THM 200-C transmissions.

Pump Body Assembly

Models

Order Service Part

BH, PS, CZ, JY, 

OI, OR, OU

8638922

Oil Pump Cover

Models

Order Service Part

CZ, JY

8633956

OR, OU

8633957

BH, PS, OI

8633958

Pump to Case Gasket

Models

Order Service Part

BH, PS, CZ, JY, 

OI, OR, OU

8633899

Refer to your service manual for disassembly and reassembly procedures.