Positive Crankcase Ventilation Valve: Service and Repair

PCV Valve

REMOVE OR DISCONNECT

1. PCV valve cover plate fastening bolts.
2. Cover plate and gasket.
3. Spring, PCV valve, and O-ring.
4. Clean old gasket material from surfaces.

INSTALL OR CONNECT

1. O-ring, PCV valve and spring.
2. Cover plate and new gasket.
3. Cover plate fastening bolts.