pontiac Workshop Repair Guides

Pontiac Bonneville V6-3800 38L Supercharged Workshop Manuals

Expansion (Orifice) Tube - Revised Installation|Page 7823 > < Evaporator Core|Removal|Page 7818
Page 1
background image

Expansion Block/Orifice Tube: Technical Service Bulletins
Expansion (Orifice) Tube - Revised Installation

Group Ref.: HVAC
Bulletin No.: 431201
Date: January, 1994

SERVICE MANUAL UPDATE

SUBJECT:
SECTION 1B OR ESM - REVISION TO ON-VEHICLE SERVICE FOR EXPANSION (ORIFICE) TUBE

MODELS:
1992-94 BUICK PARK AVENUE AND LESABRE 
1992-94 OLDSMOBILE NINETY EIGHT AND EIGHTY EIGHT 
1992-94 PONTIAC BONNEVILLE

When using the On-Vehicle service for the expansion tube, ("Install or Connect" procedure), the Service Manual states that the expansion tube should be
installed with the short screen toward the condenser. This is incorrect. The expansion tube should be installed with the short screen toward the
evaporator.

Expansion (Orifice) Tube - Revised Installation|Page 7823 > < Evaporator Core|Removal|Page 7818