pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Surge Tank Replacement|Page 2678 > < Surge Tank Replacement|Page 2676
Page 3
background image

2. Position the surge tank outlet hose and the quick connect fitting with the surge tank and press to engage. Verify the quick connect fitting is fully

seated.

3. Position the surge tank (1) on the mounting studs. 

4. Install the secondary AIR relay bracket (1) over the studs.

Notice:  Refer to Fastener Notice in Service Precautions.

5. Install the 2 secondary AIR relay bracket nuts (2). 

^

Tighten the nuts to 6 Nm (53 inch lbs.).

6. Install the surge tank nuts (2). 

^

Tighten the nuts to 6 Nm (53 inch lbs.).

7. Install the surge tank retainer.

Surge Tank Replacement|Page 2678 > < Surge Tank Replacement|Page 2676