Bonneville V8-4.6L VIN Y (2004)
1. Install the thermostat and a new gasket into the water pump housing.
2. Install the thermostat housing.
Notice: Refer to Fastener Notice in Service Precautions.
3. Install the thermostat housing bolts.
^
Tighten the thermostat housing bolts to 10 Nm (89 inch lbs.).
4. Position the J 38185 to the clamp in order to connect the radiator outlet hose to the thermostat housing.
5. Install the air cleaner assembly.
6. Fill the cooling system.