pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Air Duct > < HVAC System - Automatic|Page 6914
Page 5
background image

1. Install the recirculation actuator.

NOTE:  Refer to Fastener Notice in Service Precautions.

2. Install the recirculation actuator retaining screws.

Tighten
Tighten the screws to 1.4 N.m (12 lb in).

3. Install the electrical connector to the recirculation actuator.
4. Reposition the I/P wiring harness.

5. Position the DIM module bracket to the original position.
6. Install the rear 2 DIM module bracket retaining screws.

Tighten
Tighten the screws to 1.4 N.m (12 lb in).

7. Install the DIM module into the bracket.
8. Install the right sound insulator.
9. Install the I/P storage compartment door.

10. Recalibrate the actuator. Refer to Re-Calibrating Actuators.

Air Duct > < HVAC System - Automatic|Page 6914