pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Sensors and Switches - Computers and Control Systems > < Powertrain Control Module|Page 3501
Page 2
background image

below. Refer to the Off- Board procedure in Service Programming System (SPS) in Programming.

1. Install the PCM (1).
2. Install the PCM connectors.

NOTE:  Refer to Fastener Notice in Service Precautions.

Tighten the PCM connectors screws to 8 N.m (71 lb in).

3. Install the air cleaner cover (3) onto the air inlet housing.
4. Snap the assembly clamps into place.

5. Align the intake air duct/resonator assembly (3) into place.
6. Install the screw onto the intake air duct/resonator assembly.

Tighten the intake air duct clamp to 3 N.m (27 lb in).

7. Connect the battery negative cable.
8. Program the PCM. Refer to Service Programming System (SPS) in Programming.  See: Testing and Inspection/Programming and Relearning