pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Engine - Hard Start/Poor Warm Up Performance|Page 2577 > < Engine - Hard Start/Poor Warm Up Performance|Page 2575
Page 1
background image

Choke Pull-off: Description and Operation

When a sudden increase in manifold vacuum is sensed by the valve, the orifice within the valve delays vacuum to the carburetor choke vacuum
break. 

The length of the delay is dependent on the magnitude of the vacuum increase--the greater the increase the greater the delay.