pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

A/C System - Will Not Heat Up or Cool Down Sufficiently|Page 8164 > < A/C System - Will Not Heat Up or Cool Down Sufficiently
Page 2
background image

1.

Figure 2 shows a cable that is significantly misadjusted. As can be seen, (with the temperature knob set to the mid position) the pulley is skewed
toward the full hot side.

The proper adjustment will show the pulley skewed (5-10°) toward the full cold side (Figure 3). The 5-10° skewing toward the full cold side (with the
control knob in the mid position) assures that the door will be fully closed when the knob is in the full cold position Air loading on the door in the full
hot position assures that the door will be closed when in full hot.

2.

With some cables, there is not enough tension on the spring to keep the spring from shifting when the knob is turned and the blower is on high.
The ball slugs on the wires may have been improperly staked and the spring needs be tensioned and the cable readjusted to function properly. A
small spring retainer, P/N 10282056, will be needed.

A/C System - Will Not Heat Up or Cool Down Sufficiently|Page 8164 > < A/C System - Will Not Heat Up or Cool Down Sufficiently