If the Headlight Doors open, go to the Headlight Door Module Test.

^

If a Headlight Door does not open, check the wiring to the suspect Headlight Door Motor. If OK, replace Headlight Door Motor.

CIRCUIT OPERATION

Battery voltage to open and close the Headlight Doors is applied to terminals B and E of the headlight Door Module connector C1. The module is
grounded at terminal D of connector C1.

OPENING SEQUENCE

When the Light Switch is in Headlight or Daytime Running Lights (if so equipped) are in the night mode, battery voltage is applied to both terminals A
and C of the Headlight Door Module connector C1. With  battery voltage applied to the Input C and Input A, the Headlight Door Module's relay remains
deenergized. Battery voltage remains applied to the Headlight Door Motors through terminal B and terminal C of module connector C2. The motors are
controlled by the module switching the ground path. The Headlight Door Motors operate to open the Headlight Doors. When the doors are fully open the
module turns off the motors.

NOTE:

Measuring voltage at the motor outputs of the Headlight Door Module is NOT a valid diagnosis procedure. The module rapidly pulses
the door motors on (hi) and off (low). The pulsing is too rapid to see or measure with a voltmeter. When the pulse signal is low the
spinning door motor acts like a generator. The module can detect the voltage produced by the the motor and continues the pulsing
signal. Each door motor stops turning when its headlight door is fully open, fully closed or jammed. Once the motor stalls, no voltage
is produced and the module turns off the motor. If a motor runs longer than approximately 6 seconds (disconnected drive linkage) the
module will turn off the motor.

CLOSING SEQUENCE

When the Light Switch is pressed OFF, battery voltage is removed from terminals A and C of connector C1 at the Headlight Door Module. The Module
allows the doors to close when it sees a ground, through the many parking and instrument lights, at terminal C of connector C1. The module energizes its
relay and the relay switches move to the door-close position. Battery voltage is applied to the Headlight Door Motors through terminal A and terminal D
of module connector C2. The motors are controlled by the module switching the ground path. The Headlight Door Motors operate to close the Headlight
Doors. When the doors are fully closed the module turns off the motors.

NOTE:

Measuring voltage at the motor outputs of the Headlight Door Module is NOT a valid diagnosis procedure. See Opening Sequence for
additional information.