pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

A/C - Odor at Start up in Humid Climates|Page 7916 > < A/C - Odor at Start up in Humid Climates|Page 7914
Page 2
background image

REMOVE OR DISCONNECT

1. Recover refrigerant. Refer to "Refrigerant Recovery and Recycling, Adding Oil, Evacuating and Recharging Procedures."
2. Electrical connector at refrigerant pressure sensor (22).
3. Strap (34) from evaporator tube (8).
4. Receiver and dehydrator tube.
5. Bolt/screw (12).
6. Evaporator tube fitting at receiver and dehydrator (4).

^

Use a back-up wrench to hold receiver and dehydrator port while loosening evaporator tube fitting.

7. Evaporator tube fitting at thermostatic expansion valve (6).
8. Evaporator tube (8).

^

Discard O-rings (14).

INSTALL OR CONNECT

1. Clean evaporator tube fittings with mineral base 525 viscosity refrigerant oil.

^

Do not allow refrigerant oil to enter evaporator tube (8).

A/C - Odor at Start up in Humid Climates|Page 7916 > < A/C - Odor at Start up in Humid Climates|Page 7914