pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Accumulator HVAC|Service and Repair|Page 7626 > < Wheel Fastener|Front|Page 7621
Page 1
background image

Accumulator HVAC: Service and Repair

ACCUMULATOR REPLACEMENT

TOOLS REQUIRED

J 39400-A Halogen Leak Detector

REMOVAL PROCEDURE

1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
2. Remove the A/C compressor hose assembly bolt from the accumulator.
3. Remove the accumulator bolt (2) from the module.
4. Remove the accumulator hose bracket nut (1) from the strut tower.
5. Remove the accumulator bracket bolt.
6. Remove the accumulator from the bracket.
7. Discard the O-rings.

INSTALLATION PROCEDURE

1. Add the proper amount of PAG oil. Refer to Refrigerant System Capacities.
2. Install the new O-ring.
3. Install the accumulator to the bracket.

NOTE:  Refer to Fastener Notice in Service Precautions.

4. Install the accumulator bracket bolt.

Accumulator HVAC|Service and Repair|Page 7626 > < Wheel Fastener|Front|Page 7621