4. Install the bolt attaching the inlet and outlet heater hose bracket to the mid rail.

Tighten
Tighten the heater hose bracket bolt to 14 N.m (10 lb  ft).

5. Install the inlet and outlet heater hoses to the water pump.
6. Fill the cooling system. Refer to Draining and Filling Cooling System.