pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Air Duct > < Air Temperature Actuator Replacement|Page 14069
Page 2
background image

Important:  The key should be in the OFF position when connecting the electrical connectors to ensure proper calibration.

1. Install the recirculation actuator.

Notice:  Refer to Fastener Notice.

2. Install the recirculation actuator screw.

Tighten the screw to 2.2 N.m (19 lb in).

3. Install the recirculation electrical connector.
4. Install the I/P retainer. 
5. Install the fuse labeled HVAC CTRL (BATT).

Important:  Do not adjust any controls on the HVAC control assembly while the HVAC control assembly and actuators are calibrating. If
interrupted improper HVAC performance will result.

6. Start the engine and let run for one minute.

Air Duct > < Air Temperature Actuator Replacement|Page 14069