Using Fused Jumper Wires

USING FUSED JUMPER WIRES

TOOLS REQUIRED

J 36169-A Fused Jumper Wire

IMPORTANT:  A fused jumper may not protect solid state components from being damaged.

The J 36169-A includes small clamp connectors that provide adaptation to most connectors without damage. This fused jumper wire is supplied with a
20-A fuse which may not be suitable for some circuits. Do not use a fuse with a higher rating than the fuse that protects the circuit being tested.

AFL/ECP Connectors

AFL/EPC CONNECTORS

TOOLS REQUIRED

J-38125 Terminal Repair Kit

REMOVAL PROCEDURE

Follow the steps below in order to remove terminals from the connector.

1. For connectors with a bolt in the dress cover, turn the bolt counterclockwise to remove the connector from the component.