Pedal Positioning Sensor: Procedures

 

BRAKE PEDAL POSITION SENSOR CALIBRATION

CALIBRATION CRITERIA

The brake pedal position sensor (BPPS) receives a low reference signal and a 5-volt reference signal from the BCM. Whenever the brake pedal is
applied, the BPPS applies a variable voltage signal to the BCM through the stop lamp switch signal circuit. The BPPS calibration must be performed
after the BPPS or body control module (BCM) have been serviced. The calibration procedure will set BPPS home value. This value is used by the
BCM to determine the action of the driver applying the brake system and to provide this information to the vehicle subsystems via the class 2
communication bus.

CALIBRATION PROCEDURE

-

Install a scan tool. 

-

Turn ON the ignition, with the engine OFF.

-

Select Diagnostics.

-

Select the vehicle.

-

Select Body and Accessories.

-

Select Lighting Systems.

-

Select Special Functions.

-

Select BCM.

-

Select the BPPS calibration procedure and follow the directions displayed on the screen.