2. Install the air temperature actuator.

Notice:  Refer to Fastener Notice.

3. Install the air temperature actuator screws.

Tighten the screws to 1.5 N.m (13 lb in).

4. Close the I/P compartment door. Refer to Instrument Panel Compartment Replacement.
5. Install the fuse labeled HVAC CTRL (BATT).

Mode Actuator Replacement

Mode Actuator Replacement

Removal Procedure

1. Remove the fuse labeled HVAC CTRL (BATT).
2. Remove the left closeout panel.
3. Remove the knee bolster.