G6 L4-2.4L (2007)
Important: Inspect the CMP sensor for damage, replace as necessary.
1. Lubricate the CMP sensor O-ring seal with clean engine oil.
2. Install the CMP sensor. Intake CMP shown, exhaust CMP similar.
Notice: Refer to Fastener Notice.
3. Install the CMP sensor bolt.
Tighten the bolt to 10 N.m (89 lb in).
4. Connect the exhaust CMP sensor electrical connector (2).