pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Compressor Hose Assembly Replacement|Page 15121 > < Compressor Hose Assembly Replacement|Page 15119
Page 1
background image

Hose/Line HVAC: Service and Repair
Liquid Line Replacement

LIQUID LINE REPLACEMENT

TOOLS REQUIRED

J 39400-A Halogen Leak Detector

REMOVAL PROCEDURE

1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging.
2. Remove the refrigerant pressure sensor wire harness connector.
3. Remove the refrigerant pressure sensor.

4. Remove the liquid line bracket bolt.
5. Remove the air cleaner assembly.
6. Remove the surge tank from the surge tank bracket.
7. Remove the suction hose and liquid line nut from the thermal expansion valve (TXV).
8. Remove the suction hose and liquid line from the TXV.

9. Remove the suction hose from the dash clip.

Compressor Hose Assembly Replacement|Page 15121 > < Compressor Hose Assembly Replacement|Page 15119