pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Brake Pedal Position Sensor Calibration|Page 13542 > < Brake Lamp Relay|Locations
Page 1
background image

Brake Light Switch: Service and Repair
Brake Pedal Position Sensor Calibration

Brake Pedal Position Sensor Calibration

Calibration Criteria

Important:  Do not apply the brake pedal during the brake pedal position sensor calibration procedure. Any movement of the brake pedal
during this procedure will cause the calibration procedure to fail. If this occurs, the brake pedal position sensor (BPPS) calibration must be
repeated.

Brake pedal position sensor calibration must be performed after the brake pedal position sensor or body control module (BCM) have been serviced. The
calibration procedure will set the brake pedal position sensor home value. This value is used by the BCM to determine the action of the driver applying
the brake system and to provide this information to the vehicle subsystems via the GMLAN communication bus.

Calibration Procedure

1. Apply the parking brake.
2. Place the transmission in the PARK position.
3. Install a scan tool.
4. Clear all BCM DTCs before proceeding.
5. Navigate to the Vehicle Control Systems menu.
6. Select Module Setup menu item.
7. Select BCM menu item.
8. Select the BPP Sensor Calibration procedure and follow the directions displayed on the screen.

Brake Pedal Position Sensor Calibration|Page 13542 > < Brake Lamp Relay|Locations