pontiac Workshop Repair Guides

Pontiac Workshop Service and Repair Manuals

Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Intake|Page 4087 > < Variable Valve Timing Solenoid|Locations|Page 4084
Page 1
background image

Variable Valve Timing Solenoid: Service and Repair
Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Intake

CAMSHAFT POSITION ACTUATOR SOLENOID VALVE SOLENOID REPLACEMENT - BANK 1 (RIGHT SIDE) INTAKE

Removal Procedure

1.  Remove the air cleaner assembly.
2.  Remove the air conditioning (A/C) line push pin retainer and reposition the line out of the way.
3.  Loosen the bank 1 intake camshaft position (CMP) actuator solenoid valve bolt enough to disconnect the engine wiring harness electrical

connector from the CMP actuator solenoid valve.

4.  Disconnect the engine wiring harness electrical connector (7) from the CMP actuator solenoid valve.

5.  Remove the CMP actuator solenoid valve bolt.
6.  Remove the CMP actuator solenoid valve.
7.  Inspect the CMP actuator solenoid valve seal and replace as necessary.

Installation Procedure

Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Intake|Page 4087 > < Variable Valve Timing Solenoid|Locations|Page 4084